NSC Fire Control Panel

Modular, intelligent Hybrid Fire Control Panel
Range.
Supports Hochiki ESP and Apollo XP95/Discovery detectors.
2–18 loops in one standard housing.
Brand new touch control panel.
Graphics LCD module 240 x 64 as standard included on basic model.
Integral Power supply 24 V DC with max. 6.7 A or 4.2 A as standard included.
32 bit high performance CPU.
Flash memory up to 8 MB and RAM memory up to 8 MB.
Many powerful features included.
Configuration software operated via Modem or USB interface.
Full redundant main board and full redundant loop cards as options.

NSC Fire Control Panel

communication but it pro-
3 separate power outputs for transmission device /
sounders / strobes
USB interface for configuration by PC
Up to 8 programmable push buttons
Redundant RS-485 interface
3 x RS-232 interfaces
2 monitored conventional zones
16 digital outputs, programmable
8 digital inputs, monitored for “open-circuit”
4 relay change over contacts, programmable
Event log with max. 10,000 messages

ZFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE PANELS

touchscreen-controlled, a breeze to install, provides clear and constant feedback on all aspects of fire alarm
system activity and is fully compliant with EN54 parts 2, 4 & 13 Picture ENVISION – a powerful,intuitive and feature-rich range of
2 to 8 loop analogue addressable fire panels.

XFP 1-2 LOOP NETWORKABLE

ANALOGUE ADDRESSABLE FIRE PANELS

• Third-party certified to EN54 parts 2 and 4 by the LPCB.
• Full compatibility with the range of smoke and heat detectors, call points, sounders and control modules.
• Three access levels – 1 (general), 2 (authorized user) and 3 (engineer)
• Combined keypad/key switch entry to access levels 2 and 3
• The ability to interconnect up to eight XFP main panels (any variant)
• plus an additional four XFP repeater panels per main onto a two wire RS485 network.

XFP 1-2 LOOP NETWORKABLE
ANALOGUE ADDRESSABLE FIRE PANELS

• 4Two independently programmable conventional sounder circuits. 4Two independently programmable conventional sounder circuits.
• 4Two programmable inputs.
• 4A fault output relay and three programmable relay outputs with voltage fre changeover contacts.
• 4Three zone dependency functions (A, B & C to EN54-2 Clause 7.12)
• 4A day/night (building occupied/unoccupied) function.
• 4An investigation delay period function.
• 4Individual sensitivity settings for each device.
• 4A phased evacuation and delays to outputs facility (to EN54-2 Clause 7.11)
• 4An alarm counter that records the number of times the panel has been in an alarm state (to EN54-2 Clause 7.13).
• 4Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
• 4An integral EN54 switch mode PSU rated @ 185-260V a.c. 50/60Hz (3A on 32 zone panel, 1.4A on 16 zone panel).
• 4Adjustable contamination levels.
• 4Earth fault monitoring.
• 4Push button access code or key switch entry to Access Levels 2 and 3 (depending on model purchased).
• 4An easy to read, 80 character back-lit display.
• 440 characters of custom text per device.
• 4999 event monitoring.
• 4Comprehensive test facilities (to EN54-2 Clause 10) and a wide range of maintenance and commissioning functions including auto- learn loops,
• monitor a point, test outputs, one man walk test and loop continuity test).
• 4An intuitive Windows based upload-download PC program that allows the system to be programmed quickly and easily.

  Input/output unit with isolator

Compliant with EN54-17 & 18 (2005), the Input/Output Unit supervises one or more normally-open switches connected to a single pair of cables.

It is set to return an analogue value of 4 in the event of an open or short-circuit fault and 16 during normal operation. The status of the inputs is reported by means of two input bits. The change-over contacts are operated by an output bit.

The Input/Output unit is fitted with a bi-directional short-circuit isolator and will be unaffected by loop short-circuits on either loop input or output.

ZONE MONITOR WITH ISOLATOR

conventional fire detectors from a loop of Context Plus analogue addressable detectors and interfaces.

The Zone Monitor is factory preset to return an analogue value of 16 when all detectors on the zone are in quiescent state and 64 when a detector changes to the alarm state.

The Zone Monitor latches in the alarm state.

5.1kΩ end-of-line resistor is fitted to detector cables for open-and short-circuit faults.

Alternatively, an active end-of-line monitor may be used in conjunction with Diode bases and a capacitor of up to 50µF fitted at the Zone Monitor wiring terminals.

In either case an analogue value of 4 is transmitted during open- or short-circuit faults. The Zone Monitor is fitted with a bi-directional short circuit isolator and will be unaffected by loop short circuits on either the loop input or loop output.

SOUNDER CONTROL UNIT WITH ISOLATOR

The Sounder Control Unit allows sounders to be operated continuously or pulsed, 1 second on,1 second off. Sounders may be operated individually or in groups and, whichever address mode has been applied, may be synchronised when in
pulsed operation.
An opto-coupled input is provided to monitor the state of the external power supply.
In normal operation the Sounder Control Unit returns a pre-set analogue value of 16, but in the event of an open or short-circuit fault or of a fault in the external power supply, the unit returns a pre-set analogue value of 4.
The Sounder Control Unit is fitted with a bi-directional short-circuit isolator and will be unaffected by loop short-circuits on either loop input or output.